Technical Parameter
Specifiation: | DIN EN 60 664 / DIN EN 61 984 |
Power region | |
Rated current: | 80A |
Rated voltage: | 830V |
Rated pulse voltage: | 6kV |
Pollution level: | 3 |
Parameters at pollution level 2: | 80A 1000V 8kV 2 |
Safe zone | |
Rated current: | 16A |
Rated voltage: | 400V |
Rated pulse voltage: | 6kV |
Pollution level: | 3 |
Parameters at pollution level 2: | 16A 400/690V 6kV 2 |
Rated voltage according to UL/CSA: | 600V/300V |
Insulation resistance: | ≥1010Ω |
Material: | 聚碳酸酯 Polycarbonate |
Operating temperature: | -40℃~+125℃ |
Flame retardant grade: | V0 |
Removable times: | ≥500 |
Inserting pin
Power region | |
Material: | 铜合金 Copper Alloy |
Surface: | 镀银 Hard-silver Plated |
Contact resistance: | ≤0.3mΩ |
Screw Terminal | |
Wire Gauge: | 1.5-16mm2 |
AWG: | 16-6 |
Tightening torque | |
mm2: | 1.5 2.5 4 6 10 16 |
N.m: | 1.2 2 3 3 3 3 |
Strip length: | 14mm |
Signal zone | |
Material: | 铜合金 Copper Alloy |
Surface: | 镀银 Hard-silver Plated |
Contact resistance: | ≤1mΩ |
Screw Terminal | |
Wire Gauge: | 0.5-2.5mm2 |
AWG: | 20-14 |
Tightening torque: | 0.5Nm |
Strip length: | 7.5mm |
Current carrying capacity
Current carying capacity
The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals.
Measuring and testing techniques according to DIN EN 60512-5.
TYPE | NAME | Rated voltage | Rated current | Contacts number | 3D upload | 2D upload |
HK-004/0-M | bination inserts Screw terminal 4/0+PE Male | 830V/400V | 80A/16A | 4/0+PE |
|
|
HK-004/0-F | HK Combination inserts Screw terminal 4/0+PE Female | 830V/400V | 80A/16A | 4/0+PE |
|
Dimensions